fuel stations – as an element of LPG gas distribution infrastructure,
Tanks for polyols and isocyanates
Aboveground LPG tanks
CGH above-ground LPG tanks offer reliability, high quality, and safety in the storage of propane and propane-butane mixtures. Thanks to carefully selected materials and advanced production technologies, our tanks meet all standards and norms, guaranteeing ease of use and maximum safety. Equipped with certified fittings and anti-corrosion protection, CGH tanks are an ideal solution for fuel stations, industry, and heating systems. Their versatility, durability, and the ability to adapt parameters to individual needs make them the best choice for demanding customers. By investing in CGH LPG tanks, you choose quality and efficiency that pays dividends for years.
Applications of CGH aboveground LPG tanks
CGH aboveground LPG tanks are used in:
industry – for gas storage in technological processes,
heating systems – as an energy source for building and domestic hot water heating.
We adapt designs to the specific nature of customers’ production processes.
Intended use
Designed with diverse needs in mind, CGH aboveground LPG tanks are suitable wherever reliable and safe gas storage is required. Their robust construction and wide range of capacities allow adaptation to any project, regardless of scale.
Technical data of CGH above-ground LPG tanks
Description:
- Anti-corrosion protection: coating to class C3M or higher.
- Personalisation option: adaptation to specific customer requirements.
CGH aboveground LPG tanks – optional equipment
- Fittings adapted to customer specification – increased tank functionality.
- Level gauges – monitoring the amount of gas in the tank.
- Sun shields – increased resistance to heating.
- Service ladders and platforms – facilitating operation and maintenance.
External tank surface
CGH LPG tanks are coated with corrosion protection in class C3 M or higher, ensuring:
- resistance to variable weather conditions,
- protection against mechanical damage,
- an aesthetic appearance that is maintained for years.
Advantages of CGH aboveground LPG tanks
Safety at the highest level – made from certified carbon steel, meeting all safety standards.
Resistance to weather conditions – anti-corrosion protection to class C3 M guarantees durability and protection against damage.
Versatility of applications – ideal for industry, fuel stations, and heating systems.
Completeness: The LPG tank design includes a full set of nozzles and fittings required for various tank operating modes.
Energy efficiency – minimisation of gas losses thanks to precisely designed components.
Easy maintenance – thanks to the inspection manhole and access to fittings, servicing is quick and convenient.
| Tank capacity | Diameter | Length* | Height | Weight | Distance between supports |
|---|---|---|---|---|---|
| [m3] | [mm] | [mm] | [mm] | [kg] | [mm] |
| 9 | 1250 | 7 650 | 2120 | 1756 | 6375 |
| 9,9 15 | 1600 | 5330 7830 | 2470 | 2343 3113 | 3700 6200 |
| 9,9 14,5 20,5 25 29,8 36,1 40,7 45,4 50,0 54,7 57,8 | 2000 | 3 540 5 040 7 040 8 540 10 040 12 040 13 540 15 040 16 540 18 040 19 040 | 2 870 | 2 354 3 039 3 953 4 638 5 450 6 364 7 049 7 754 8 439 9 124 9 124 | 1 500 3 000 5 000 6 500 8 000 10 000 11 500 13 000 14 500 16 000 17 000 |
| 42,5 52 62 71 77 81 86 91 | 2500 | 9290 11290 13290 15290 16290 17290 18290 19290 | 3 370 | 7418 8804 10352 11737 12450 13143 13999 14691 | 6750 8750 10750 12750 13750 14750 15750 16750 |
| 61,5 71,5 84,5 97,5 110 120 125 138 150 | 2900 | 10000 11500 13500 15500 17500 19000 19500 21500 23500 | 3 770 | 10894 12300 14293 16168 18042 19448 19917 21910 23784 | 7050 8550 10550 12550 14550 16050 16550 18550 20550 |
| 150 200 | 3200 | 19740 26240 | 4 070 | 25738 33561 | 16400 22900 |
| 150 200 250 300 | 3400 | 17840 23840 28840 34840 | 4 270 | 26667 35073 42162 50568 | 14300 20300 25300 31300 |
| 150 200 2500 300 | 3600 | 15960 20960 25960 30960 | 4 470 | 28462 36352 44751 53150 | 12200 17200 22200 27200 |
* Total length within a tolerance of +/-0.5% in accordance with the standard.
** The actual distance will be shown on the drawing in accordance with structural calculations.